繁體版 English РусскийไทยViệt
登录 注册

血氧饱和度

"血氧饱和度"的翻译和解释

例句与用法

  • This thesis elaborates a self - developed measuring equipment for pulse oximetry . this unit can output the standard oximetry test signal comparatively with difference sensors of the tested pulse oximetry , include pulse rate , peep and oxygen saturation
    所述脉搏血氧仪校准装置,它能产生一个与被检脉搏血氧仪传感器类型相对应的标准血氧测试信号,包括脉率、脉冲幅度和血氧饱和度
  • This project mainly studies the effects of breathing 70 % oxygen on hemorheology after incremental exercise to exhaustion . the blood viscosity ( bv ) , plasma viscosity ( pv ) , erythrocyte aggregation index ( al and a2 ) , erythrocyte deformability index ( tk ) , erythrocyte rigid index ( vr ) and hematocrit ( hct ) were obtained and analyzed . the vo2 max , hl , hr and po2 were measured and analyzed quantitatively as well
    本文观察了一次性递增负荷至力竭运动以及运动后吸入高浓度氧对血液流变性的影响,通过对运动后血液流变学指标与最大吸氧量、血氧饱和度、血乳酸、心率等指标作多因素相关分析,为运动影响血液流变学的原因和机制的研究提供一定的实验依据。
  • So in this paper , the principle of electroptical non - invasive dual - ray methods are fist present in detail . in the theorem of simple structure and low power consumption , we select detecter with fitble wavelenth and low power msp430 processor , and design high stable ray - emitt circuit , low noise pre - amplifier , background disturbance counteract circuit , the signal are low - filtered and sent to msp430 " a / d transform directly to digital signal processing
    为此,本文详细分析了光电无创双光束法测定脉搏血氧饱和度的基本原理,在结构简单,功耗小的原则下,选用合适发光波长的探头和信号处理器,设计出光强稳定的发光电路,低噪声前级,以及本底干扰对消电路,通过两级低通直接送至ti公司的超低功耗混合信号处理器msp430进行a / d变换得到原始的数字信号。
  • Determining oxygen saturation in human blood by transmittance oxymetry is well developed as a monitoring technique , which is applied widely in clinical diagnosis or house health care . however , reflectance detecting is necessary in many circumstances , such as cerebral oxygen saturation , muscle oxygen saturation , or fetal oxygen saturation monitoring . how to get an exact and dependable reflectance oxygen saturation value by non - invasive and economic means is always concerned by researchers in biomedical engineering
    采用透射式检测方法确定人体血液中的氧饱和度已经是较为成熟的监护手段,在临床和家庭保健场合有广泛的应用;但在很多需要进行反射检测的场合,如脑血氧、肌血氧、胎儿血氧监护等,如何用无创、经济的方法获得准确、可靠的血氧饱和度值仍是生物医学工程领域不断在探索的问题。
  • However , a new method is brought forward when dealing with alternating components of emitting light in reflectance detection , which entirely reflect the concentration of oxy - hemoglobin and deoxy - hemoglobin in blood , to improve the system sensitivity on oxygen saturation alternation . the new method is an innovative reference to reflectance oxygen saturation detection
    在对检测到的完全反应血液中氧合血红蛋白和脱氧血红蛋白含量变化的脉动分量的处理上,由于透射检测中的处理方法用于反射时灵敏度降低,论文中提出了一种新的能更灵敏反应血氧变化的参量作为确定血氧饱和度的依据。
  • At first , the principle and technique employed in transmittance oxymetry is analyzed . the lambert - beer law and the difference in extinction coefficient of components in tissues relate to different light wavelength is applicable in reflectance oximetry as well as in transmittance oximetry , as both are relate to near - infrared spectroscopy
    本文在深入了解透射式血氧饱和度测定原理及其方法之后,首先明确用近红外光谱法测定组织血氧饱和度时,无论是透射式检测手段还是反射式检测,其依据的基本原理都是lambert - beer定律和组织中各成分对应不同波长光的吸收系数的差异。